1.
Adv Sci (Weinh) ; 11(16): e2307929, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38417124

RESUMO

In this study, a novel, high content technique using a cylindrical acoustic transducer, stroboscopic fast imaging, and homodyne detection to recover the mechanical properties (dynamic shear modulus) of living adherent cells at low ultrasonic frequencies is presented. By analyzing the micro-oscillations of cells, whole populations are simultaneously mechanotyped with sub-cellular resolution. The technique can be combined with standard fluorescence imaging allowing to further cross-correlate biological and mechanical information. The potential of the technique is demonstrated by mechanotyping co-cultures of different cell types with significantly different mechanical properties.


Assuntos
Estroboscopia , Humanos , Estroboscopia/métodos , Adesão Celular/fisiologia , Som , Imagem Óptica/métodos , Animais
2.
Adv Healthc Mater ; : e2303785, 2024 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-38221504

RESUMO

Type 2 diabetes mellitus (T2DM), obesity, and metabolic dysfunction-associated steatotic liver disease (MASLD) are epidemiologically correlated disorders with a worldwide growing prevalence. While the mechanisms leading to the onset and development of these conditions are not fully understood, predictive tissue representations for studying the coordinated interactions between central organs that regulate energy metabolism, particularly the liver and pancreatic islets, are needed. Here, a dual pump-less recirculating organ-on-chip platform that combines human pluripotent stem cell (sc)-derived sc-liver and sc-islet organoids is presented. The platform reproduces key aspects of the metabolic cross-talk between both organs, including glucose levels and selected hormones, and supports the viability and functionality of both sc-islet and sc-liver organoids while preserving a reduced release of pro-inflammatory cytokines. In a model of metabolic disruption in response to treatment with high lipids and fructose, sc-liver organoids exhibit hallmarks of steatosis and insulin resistance, while sc-islets produce pro-inflammatory cytokines on-chip. Finally, the platform reproduces known effects of anti-diabetic drugs on-chip. Taken together, the platform provides a basis for functional studies of obesity, T2DM, and MASLD on-chip, as well as for testing potential therapeutic interventions.

3.
Bioengineering (Basel) ; 10(7)2023 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-37508838

RESUMO

This paper presents an innovative experimental setup that employs the principles of audio technology to subject adherent cells to rhythmic vertical vibrations. We employ a novel approach that combines three-axis acceleration measurements and particle tracking velocimetry to evaluate the setup's performance. This allows us to estimate crucial parameters such as root mean square acceleration, fluid flow patterns, and shear stress generated within the cell culture wells when subjected to various vibration types. The experimental conditions consisted of four vibrational modes: No Vibration, Continuous Vibration, Regular Pulse, and Variable Pulse. To evaluate the effects on cells, we utilized fluorescence microscopy and a customized feature extraction algorithm to analyze the F-actin filament structures. Our findings indicate a consistent trend across all vibrated cell cultures, revealing a reduction in size and altered orientation (2D angle) of the filaments. Furthermore, we observed cell accumulations in the G1 cell cycle phase in cells treated with Continuous Vibration and Regular Pulse. Our results demonstrate a negative correlation between the magnitude of mechanical stimuli and the size of F-actin filaments, as well as a positive correlation with the accumulations of cells in the G1 phase of the cell cycle. By unraveling these analyses, this study paves the way for future investigations and provides a compelling framework for comprehending the intricate cellular responses to rhythmic mechanical stimulation.

4.
Biosensors (Basel) ; 11(5)2021 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-34069506

RESUMO

Polydimethylsiloxane (PDMS) has been used in microfluidic systems for years, as it can be easily structured and its flexibility makes it easy to integrate actuators including pneumatic pumps. In addition, the good optical properties of the material are well suited for analytical systems. In addition to its positive aspects, PDMS is well known to adsorb small molecules, which limits its usability when it comes to drug testing, e.g., in organ-on-a-chip (OoC) systems. Therefore, alternatives to PDMS are in high demand. In this study, we use thermoplastic elastomer (TPE) films thermally bonded to laser-cut poly(methyl methacrylate) (PMMA) sheets to build up multilayered microfluidic devices with integrated pneumatic micro-pumps. We present a low-cost manufacturing technology based on a conventional CO2 laser cutter for structuring, a spin-coating process for TPE film fabrication, and a thermal bonding process using a pneumatic hot-press. UV treatment with an Excimer lamp prior to bonding drastically improves the bonding process. Optimized bonding parameters were characterized by measuring the burst load upon applying pressure and via profilometer-based measurement of channel deformation. Next, flow and long-term stability of the chip layout were measured using microparticle Image Velocimetry (uPIV). Finally, human endothelial cells were seeded in the microchannels to check biocompatibility and flow-directed cell alignment. The presented device is compatible with a real-time live-cell analysis system.


Assuntos
Dimetilpolisiloxanos/química , Dispositivos Lab-On-A-Chip , Elastômeros , Células Endoteliais , Humanos
5.
Soft Matter ; 16(11): 2829-2835, 2020 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-32104872

RESUMO

Spherical bubbles are notoriously difficult to hold in specific arrangements in water and tend to dissolve over time. Here, using stereolithographic printing, we built an assembly of millimetric cubic frames overcoming these limitations. Indeed, each of these open frames holds an air bubble when immersed into water, resulting in bubbles that are stable for a long time and are still able to oscillate acoustically. Several bubbles can be placed in any wanted spatial arrangement, thanks to the fabrication process. We show that bubbles are coupled acoustically when disposed along lines, planes or in 3D arrangements, and that their collective resonance frequency is shifted to much lower values, especially for 3D arrangements where bubbles have a higher number of close neighbours. Considering that these cubic bubbles behave acoustically as spherical bubbles of the same volume, we develop a theory allowing one to predict the acoustical emission of any arbitrary group of bubbles, in agreement with experimental results.

6.
Lab Chip ; 17(8): 1515-1528, 2017 04 11.
Artigo em Inglês | MEDLINE | ID: mdl-28374878

RESUMO

Acoustic micropropulsors present great potential for microfluidic applications. The propulsion is based on encapsulated 20 µm bubbles excited by a contacless ultrasonic transducer. The vibrating bubbles then generate a powerful streaming flow, with speeds 1-100 mm s-1 in water, through the action of viscous stresses. In this paper we introduce a full toolbox of micropropulsors using a versatile three-dimensional (3D) microfabrication setup. Doublets and triplets of propulsors are introduced, and the flows they generate are predicted by a theoretical hydrodynamic model. We then introduce whole surfaces covered with propulsors, which we term active surfaces. These surfaces are excited by a single ultrasonic wave, can generate collective flows and may be harnessed for mixing purposes. Several patterns of propulsors are tested, and the flows produced by the two most efficient mixers are predicted by a simple theoretical model based on flow singularities. In particular, the vortices generated by the most efficient pattern, an L-shaped mixer, are analysed in detail.

7.
Phys Rev E ; 94(3-1): 033109, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27739843

RESUMO

A theoretical model is developed for acoustic streaming generated by a cylindrical bubble confined in a fluid channel between two planar elastic walls. The bubble is assumed to undergo volume and translational oscillations. The volume oscillation is caused by an imposed acoustic pressure field and generates the bulk scattered wave in the fluid gap and Lamb-type surface waves propagating along the fluid-wall interfaces. The translational oscillation is induced by the velocity field of an external sound source such as another bubble or an oscillatory fluid flow. The acoustic streaming is assumed to result from the interaction of the volume and the translational modes of the bubble oscillations. The general solutions for the linear equations of fluid motion and the equations of acoustic streaming are calculated with no restrictions on the ratio between the viscous penetration depth and the bubble size. Approximate solutions for the limit of low viscosity are provided as well. Simulations of streamline patterns show that the geometry of the streaming resembles flows generated by a source dipole, while the vortex orientation is governed by the driving frequency, bubble size, and the distance of the bubble from the source of translational excitation. Experimental verification of the developed theory is performed using data for streaming generated by bubble pairs.

8.
Phys Rev E ; 94(2-1): 023105, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27627390

RESUMO

An analytical expression is derived for the secondary Bjerknes force experienced by two cylindrical bubbles in a microfluidic channel with planar elastic walls. The derived expression takes into account that the bubbles generate two types of scattered acoustic waves: bulk waves that propagate in the fluid gap with the speed of sound and Lamb-type surface waves that propagate at the fluid-wall interfaces with a much lower speed than that of the bulk waves. It is shown that the surface waves cause the bubbles to form a bound pair in which the equilibrium interbubble distance is determined by the wavelength of the surface waves, which is much smaller than the acoustic wavelength. Comparison of theoretical and experimental results demonstrates good agreement.